Desk plan
Four-Bay Wooden Organizer for Cables and Adapters
Give each unplugged adapter room to come out by itself.
- Width
- 13 in.
- Depth
- 6 in.
- Height
- 4¾ in.
See the labeled assembly drawing
Assembly drawing
Offcut Journal editorialUpdated
Save this plan to find it alongside your build progress on this device.
Open saved plansBefore you cut
Check the fit at your bench
The rack is 13 × 6 × 4¾ inches. Each of the four openings is 2 11/16 inches wide, with 5¼ inches of depth before the back. Measure plugs at their widest molded point and fit the intended loose coil into a mock bay. Store disconnected cords and adapters here. Leave powered equipment in its regular use location with the clearance its manufacturer specifies.
Hold the molded plug at its widest point and set the rest of the cable down in its natural coil. That is the footprint to measure. A slim plug on a stiff lead can take more room than a bulky adapter with a short cord.
The front is open so you can lift a coil without feeding its connector through a slot. All four bays start equal. If one adapter is especially wide, you can borrow space from the bay next to it by moving a single divider.
Give each unplugged cord its natural bend
Coil the cables using the radius they take when you gather them loosely in your hand. A stiff cord may stand taller and push harder against the sides than a flat one of the same length. Draw the four bays on paper and set the unplugged cords in place with the molded plugs toward the front. Reach for the easiest plug and then the deepest one. Note where a plug catches as its cable follows out of the bay. Use the largest naturally coiled cord to choose which pocket gets more space and to pick a tie that you can release easily with one hand.
Check your labels from above
A label matched to the plug or device belongs where you can read it before touching the coil. Try paper labels on the back panel and near the front edge of the base. Stand where you usually reach for the cords and see which position remains visible when all four bays are full. If the rack sits on an open shelf, a label along the base’s front edge can stay legible below the coil. Keep the labels removable so you can change the order after a charger or device leaves your setup. Include an equipment name short enough that you can distinguish two similar plugs at a glance.
Find the divider that catches a brick
Put the widest disconnected power brick in a test bay with its removable cable wound loosely beside it. Reach in from above and lift the brick with your usual hand. What catches may be a keyed plug or molded shoulder that turns outward on the way up. If the fit works only when you hold the cord flat, give that bundle a wider bay or split the cord and brick into separate spaces.
Measured drawings
Use the top view for width and depth. Use the front or right-side view to check height.
- Overall width
- 13 in.
- Overall depth
- 6 in.
- Overall width
- 13 in.
- Overall height
- 4¾ in.
- Overall depth
- 6 in.
- Overall height
- 4¾ in.
Cut list
- Cut pieces
- 5
- Stock types
- 2
- Longest part
- 13 in.
Read each blank as length × width × thickness.
Metric is a reference conversion. Match the stock and assembly dimensions in the inch plan before cutting.
Choose a part letter to highlight it in the assembly.
| Part | Piece and stock | Qty | Cut size |
|---|---|---|---|
| A | Base¾ in. plywood | 1 | 13 × 6 × ¾ in. |
| B | Back¾ in. solid wood | 1 | 13 × 4 × ¾ in. |
| C | Divider¾ in. plywood | 3 | 4¾ × 2½ × ¾ in. |
Keep the cut list, tools, build order, and final check in one offline text file.
Download project briefCheck your offcuts
Match the actual thickness or dowel diameter first. A group’s longest and widest blanks can be different pieces. Lay out each part on your stock before cutting.
-
¾ in. plywood4 pieces
- Longest blank
- 13 in.
- Widest blank
- 6 in.
Measure the sheet at several points along the edge. Use its actual thickness when checking widths between two panels.
-
¾ in. solid wood1 piece
- Longest blank
- 13 in.
- Widest blank
- 4 in.
Check both ends and the middle after surfacing. Match the actual thickness on paired rails or cheeks before marking their positions.
Allow room for the saw cuts, end trimming, and defects. Bring these part lengths to the Workbench
Supplies and tools
Supplies
- Three #6 × 1¼ in. flat-head wood screws
- Wood glue
- Reusable soft cable ties
- Paper labels or low-tack tape, optional
Tools
- Square, ruler, pencil, clamps, and three equal spacing blocks or equivalent gauges
- Drill, clearance and pilot bits, countersink, and depth stop
- Sanding block and sandpaper
See each cut blank 3 part types
Use the cut sizes below. The silhouettes are sized to fit each card.
-
ABaseCut 1
¾ in. plywood
13 × 6 × ¾ in.Length × width × thickness -
BBackCut 1
¾ in. solid wood
13 × 4 × ¾ in.Length × width × thickness -
CDividerCut 3
¾ in. plywood
4¾ × 2½ × ¾ in.Length × width × thickness
Exact part positions
Measurements start at the lower front-left corner of the drawing. Each location marks the front-left bottom corner of that piece. For a round part, it marks the corner of the square that encloses it.
| Piece | From left | From front | From bottom |
|---|---|---|---|
| A Base | 0 in. | 0 in. | 0 in. |
| B Back | 0 in. | 5¼ in. | ¾ in. |
| C Divider | 2¹¹⁄₁₆ in. | ½ in. | ¾ in. |
| C Divider | 6⅛ in. | ½ in. | ¾ in. |
| C Divider | 9⁹⁄₁₆ in. | ½ in. | ¾ in. |
Build it
0 of 5 steps checked
Browse the illustrated steps
-
1. Make two widths from cardboard
Coil each disconnected cable loosely and include the molded plug in the footprint. Cut a 2 11/16-inch cardboard gauge to check whether the proposed opening fits the widest item. For unequal bays, make gauges for both new widths and set them against the same front edge. Keep the sum of the two clear bay widths at 5⅜ inches.
Check at the bench Save room for the widest molded plug.
Dry fitTop viewGauge a bay against the adapter and its loose cable together. The four open widths can be divided differently.
-
2. Mark both sets of reference lines
Put the divider left faces 2 11/16, 6⅛, and 9 9/16 inches from the left edge. Their front faces sit ½ inch from the front edge and their rear faces touch the back wall. The back wall begins 5¼ inches from the front, flush to the rear edge.
Check at the bench Set every divider front ½ inch back.
Mark outTop viewAll three divider fronts line up behind the base edge. Their rear edges meet the face of the back wall.
-
3. Attach the back before the dividers
On the underside of the base, at y = 5⅝ inches, mark screws at x = 1½, 6½, and 11½ inches. Drill base clearance holes and countersink flush. Clamp the back to the base to mark its centered pilots, with about ½ inch of pilot depth into the back. Glue and attach the back from below.
Check at the bench Screw line is 5⅝ inches from the front.
Drill and checkUnderside layoutThe three underside clearance holes sit on the centerline of the back wall’s footprint.
Plot the marked centers
Measure from the drawing’s left and front edges. The step lists pilot depth and any remaining centers.
Mark From left From front 1 1½ in. 5⅝ in. 2 6½ in. 5⅝ in. 3 11½ in. 5⅝ in. -
4. Keep the fronts and backs in line
Glue the bottom and rear edges of the dividers and press them against the back. Set a spacer at both the front and rear of each bay so the fins stay parallel. Measure the ½-inch setback at both outside divider corners. Pull all spacers when the clamps are seated, and clear any glue ridge along the floor where a cable loop could catch.
Check at the bench Compare both ends of each bay.
Join the partsTop viewEach divider touches the wall behind it. Spacers at the front and rear keep the two sides of each opening parallel.
-
5. Give the slots clear edges
Soften the front and top edges of the dividers and the front edge of the base after cure. Put removable paper labels just above the dividers on the back wall where you can read them with the bays filled. Tie each cord loosely enough for its natural coil to keep its shape.
Check at the bench Unplugged cables should lift clear of neighboring bays.
Surface prepAssembly viewSoften the edges facing the opening and leave the upper back wall clear for labels you can read over the dividers.
My bench notes
These notes stay in this browser.
If the fit is off
Two similar adapters still get mixed up
Label by the device they belong with rather than by color. Use the same short name on the bay and on a removable tie around the disconnected cable. Keep the identification visible when the cord is coiled.
A plug gets stuck between the fins
Compare the narrowest finished opening with the widest plug housing. If a divider wandered while curing, sand only a small interference point. For an oversize plug, revise the bay widths or give the adapter a separate place rather than wedging it in.